©
Equivalent diameter
  Computes two equivalent (Sauter) diameters.
2024.Nov.25 03:38:45
Initial sieve Initial sieve opening (mm). •
Weights before Weights retained (g), before. •
Weights after Weights retained (g), after. •
Show values ? Shows the graph coordinates.

Computes the equivalent diameters ("Sauter mean diameter") before and after a treatment. The data are the quantities (weights) retained in a series of sieves. The sieves' openings are supposed to decrease by 1⁄√2.

(It is expected to include here an alternative equivalent diameter.)

The graph shows the fractions retained before and after.

References: Plate: EquivDiam

• EPA, "Characteristics of particles — size distribution", U. S. Environmental Protection Agency.

• Google search: particle size distribution mean diameter

• Wikipedia, Particle size distribution (Sauter mean diameter)

• Silver Colloids, Particle sizing: an introduction".

• Kaczmarski & Bellot, 2003, "Effect of particle-size distribution...".pdf, Acta Chromatographica, 13:22–37.

• 1881-05-11: Kármán, Theodore von (1963-05-07).

 
 
Valid HTML 4.01! IST http://web.ist.utl.pt/~mcasquilho/compute/com/Fx-equivdiam.php
Created: 2010-05-11 — Last modified: 2010-05-11